OVFEXC7=0, OVFEXC0=0, OVFEXC2=0, OVFEXC1=0, OVFEXC8=0, OVFEXC6=0, OVFEXC5=0
Extended Analog A/D Conversion Overflow Status Clear Register
OVFEXC0 | Self-diagnosis Channel: Overflow Flag Clear 0 (0): No effect 1 (1): ADOVFEXSR.OVFEXF0 is cleared |
OVFEXC1 | Temperature Sensor Channel: Overflow Flag Clear 0 (0): No effect 1 (1): ADOVFEXSR.OVFEXF1 is cleared |
OVFEXC2 | Internal Reference Voltage Channel: Overflow Flag Clear 0 (0): No effect 1 (1): ADOVFEXSR.OVFEXF2 is cleared |
OVFEXC5 | D/A Converter 0 Channel: Overflow Flag Clear 0 (0): No effect 1 (1): ADOVFEXSR.OVFEXF5 is cleared |
OVFEXC6 | D/A Converter 1 Channel: Overflow Flag Clear 0 (0): No effect 1 (1): ADOVFEXSR.OVFEXF6 is cleared |
OVFEXC7 | D/A Converter 2 Channel: Overflow Flag Clear 0 (0): No effect 1 (1): ADOVFEXSR.OVFEXF7 is cleared |
OVFEXC8 | D/A Converter 3 Channel: Overflow Flag Clear 0 (0): No effect 1 (1): ADOVFEXSR.OVFEXF8 is cleared |